How to tell if your radon mitigation system is working

Short answer: A radon system is working when the fan is running continuously, the warning device (usually a U-tube manometer) shows suction, and a radon test confirms the indoor level is where you and the EPA guidance want it. The EPA recommends fixing a home at or above 4 pCi/L, considering action between 2 and 4 pCi/L, checking the warning device regularly, retesting within 30 days after a system is installed (but no sooner than 24 hours after the fan is on), and retesting at least every two years and after remodeling. A quiet fan or a normal-looking pipe is not enough by itself.

Safety: Leave the fan running. The EPA states the fan should never be turned off; it must run continuously for the system to work correctly. If you suspect a failure, keep the system on if it still runs, ventilate as you normally would, and arrange a test and a repair. Follow EPA testing conditions: windows and doors closed for 12 hours before and during a short-term test, except for normal entry and exit.

A practical system check

  1. Look at the manometer. With the fan on, the liquid in a U-tube manometer should be uneven, showing suction in the pipe. A flat, equal reading on both sides, or a reading that has changed a lot from the installer's mark, means you should investigate. See how to read a U-tube manometer.
  2. Confirm the fan is running. You should feel a slight vibration or hear a steady hum at the fan, and often a small amount of exhaust at the vent. No sound, a loud grinding noise, or a fan that has stopped is a problem. See radon fan not working.
  3. Look at the pipe and exhaust. The riser should be intact, the couplings tight, and the exhaust clear of snow, nests or debris. If a cap is used, it must not block the discharge. See should a radon vent pipe have a cap?.
  4. Retest the air, not just the hardware. Use a short-term kit (a two- to seven-day test is what the EPA recommends to check a system's effectiveness) or a long-term kit when you want a longer average. Follow the kit instructions and closed-house conditions. See how to test your home for radon.
  5. Keep a schedule. The EPA says to retest at least every two years to be sure levels remain low, and to retest after you remodel, in the lowest lived-in area. Replace a failed fan and then test again.

What the EPA asks you to watch

The EPA's Consumer's Guide to Radon Reduction treats a mitigation system like other household equipment that needs occasional attention. For a fan-powered system, you should look at the warning device regularly. Fans may last for five years or more — manufacturer warranties tend not to exceed five years — and may then need to be repaired or replaced. The fan must run continuously.

After installation, a post-mitigation radon test should be done within 30 days, but no sooner than 24 hours after the system is in operation with the fan on. The EPA recommends a two- to seven-day measurement and says it is a good idea to have an independent follow-up test, or to conduct the measurement yourself, rather than relying only on a test by the installer. Windows and doors must be closed 12 hours before and during that test, except for normal entry and exit.

The EPA action level is 4 pCi/L. The agency also recommends that people consider fixing a home when the level is between 2 pCi/L and 4 pCi/L, because there is no known safe level of radon exposure. A system that was installed to bring a high reading down should be retested, not assumed to still be doing that job years later.

Source: U.S. Environmental Protection Agency, epa.gov/radon and the EPA Consumer's Guide to Radon Reduction (EPA 402/K-10/005).

When the hardware looks fine but you should still test

A manometer can show suction while a pipe is cracked, a suction point is blocked, or the house has been opened up by a remodel. The only way to know the indoor radon level is to measure it. Keep a short-term kit on hand for a spot check and use a long-term kit when you want a better average across seasons.

If the manometer is flat, start with the fan, power and couplings before you buy a new monitor. If the fan has reached the end of its service life, see how long a radon fan lasts and replacing a radon fan. For a parts overview, see the radon mitigation system parts checklist.

Manometers, alarms and test kits

Common questions

The manometer is uneven. Does that mean radon is low?

It means the fan is pulling a vacuum in the pipe, which is what you want to see day to day. It does not replace a radon test of the indoor air.

How soon after a new fan can I test?

The EPA says no sooner than 24 hours after the system is operating with the fan on, and a post-mitigation test should be done within 30 days of installation. Use a two- to seven-day test to check effectiveness, with closed-house conditions.

Should I turn the fan off at night or in winter?

No. The EPA says the fan should never be turned off. An active system only works while the fan is running.

Do I need a professional test?

You can use a home test kit. After a mitigation system is installed, the EPA recommends an independent follow-up measurement to avoid a conflict of interest, which can be a kit you conduct yourself or a test by a separate professional.

Shop radon mitigation supplies How to read a manometer How to test for radon Radon test kits

Related categories: Radon Mitigation Supplies. General information only; follow the equipment maker's instructions and local codes. Updated 2026-11-25.