Sump pump not turning on: check the float switch first
Short answer: If a sump pump will not start when the pit is filling, check power first (outlet, GFCI, and the circuit), then the float switch. A float that is jammed against the pit wall, tangled in the discharge pipe, or electrically failed is a common reason the pump never gets the signal to run. We sell replacement float switches and high-water alarms for this situation, not the pump motor itself. If the float lifts freely and the pump still does not run, the motor or impeller may have failed and the pump needs service or replacement.
Safety: Unplug the pump before you reach into the pit or handle the float. Do not stand in water while you reset a tripped circuit. Sewage or effluent pits are a gas and infection hazard; do not enter a tank or a deep pit. If the pit is already overflowing, move valuables, use a safe temporary pump if you have one, and call a plumber when the water involves sewage.
A safe troubleshooting order
- Check power. Confirm the pump is plugged in, the outlet is live, and a GFCI or breaker has not tripped. Reset a GFCI once. If it trips again, stop and treat that as an electrical fault, not a float adjustment.
- Look at the water level and the float. With power off, see whether the float can rise. It should move freely through its arc or slide path and not rub the pit wall, the discharge pipe, or a tangled power cord. A tethered float needs a clear swing; a vertical-switch float needs a clear rod.
- See what kind of switch you have. Many residential pumps use a piggyback float: the pump plugs into the float, and the float plugs into the wall. That design lets you replace the switch without replacing a working pump. Other pumps have a float wired into the unit. See float switch types.
- Test a piggyback switch carefully. With the pit safe and power applied only for the test, lifting a working piggyback float should start the pump, and lowering it should stop it. If the pump runs when you plug it straight into a known-good outlet (bypassing the switch only long enough to test, and not left unattended), the motor is alive and the switch is the likely failure.
- Replace a failed switch, and add a high-water alarm if you do not have one. Install a replacement float that matches the job (sump, or a sewage-rated float in a sewage pit) and the cord length you need, following the switch instructions. A high-water alarm is a separate warning if the pump or switch fails again. See sump pump high-water alarm sounding and sump and septic high-water alarms.
Other reasons the pump will not start or will not keep up
The float is the first mechanical item to check, but it is not the only one:
- A jammed impeller or debris in the intake can stall a pump that has power and a working switch. Unplug it before you clear debris.
- A frozen or blocked discharge line can make the pump run, then overheat or trip, so it later seems “dead.” Check the discharge and the check valve.
- A failed motor will not run even when it is plugged in directly. That is a pump replacement, which we do not sell here.
- A power outage is a different problem. A backup plan and an alarm matter more than a new float. See sump pump and power outages.
If the pump runs but never shuts off, the float may be held in the up position, or the switch may have failed closed. If it short-cycles, the float may be hitting the pit wall or the tether may be too short. Those are also switch-placement problems, not always a new pump.
Choosing a replacement float and an alarm
Match the float to the pit. A clean-water sump float is not automatically the right part in a sewage or septic tank; sewage-rated floats are built for that service. Cord length should reach the outlet with slack, without leaving a coil that the float can tangle in. Piggyback switches are the usual replacement when the original pump used a piggyback plug.
A high-water alarm does not start the pump. It tells you the water has risen past the point where the pump should already have run, so you can act before the room floods. Indoor and outdoor-rated alarms, longer float cords and Wi-Fi alerts are options; pick one you will actually hear or see. Place the alarm float above the pump's normal turn-on level, following the alarm instructions.
Float switches and high-water alarms
- 3100 Series Piggyback Sump Pump Float Switch — 10 Foot / Starts Pump on High Level — $46.99
- "SinkWire" Float Switch Connection Kit: Stop Premature Float Switch Failure — 1 — $14.99
- "SinkWire" Float Switch Connection Kit: Stop Premature Float Switch Failure — 10 — $85.99
- "The Original" Sump Alarm High Water Alarm — $201.99
- 12VDC High Water Alarm — 10 — $185.99
Common questions
Can I leave the pump plugged in without the float to keep the pit down?
Only as a brief, attended test. A pump with no switch can run dry and fail, or fill a blocked discharge line. Restore a working float or replace the pump as soon as you can.
The GFCI trips when the pump starts. Is that the float?
Not usually. A GFCI that trips on startup points to an electrical fault in the pump, the cord or the circuit. Do not keep resetting it. Have the electrical problem diagnosed.
Do you sell replacement sump pumps?
No. We sell float switches, connection kits and high-water alarms used with sump, effluent and septic pumps. If the motor has failed, you will need a pump from a plumbing store or a plumber.
Should I add an alarm even if the pump works now?
Yes, if you do not already have one. A working pump can still fail later, and an alarm is the usual way to find out before water reaches the floor.
Shop sump pumps and alarms Float switch types High-water alarm sounding Sump and septic alarms
Related categories: Sump & Effluent Pumps & Alarms. General information only; follow the equipment maker's instructions and local codes. Updated 2026-11-25.